CMF SURGERY
Inion's product range of biodegradable craniomaxillofacial
implants includes surgical plates, screws, instruments and
accessories for craniofacial, orthognathic and trauma surgery.
Within
each product group, several different plates and screws are
supplied for different surgical purposes.
THE IDEAL IMPLANT FOR CMF SURGERY

The
qualities for an ideal fixation system are adequate strength
and rigidity, lack of adverse tissue reactions, lack of interference
with bone healing, lack of intra-cranial migration, lack of
visibility and palpability, and avoidance of an implant removal
operation.
Surgeons
appreciate good handling properties, such as plate malleability,
good fit and easy screw pick-up, avoidance of tapping, and
screws with good torsional strength.
If you currently use titanium fixation,
Inion CPS offers these benefits:
No second procedure for removal and related cost
and trauma
Less patient complaints
No imaging interference
Reduced long-term infection risk
Progressive bone loading
Reduced potential cross infection risk
If you currently use resorbable fixation,
Inion CPS offers these benefits:
Inion CPS system can be used in any application in
CMF surgery except mandibular bridging
Optimised solution to each procedure
Tailored implant design
Easier and quicker to use
1. Description
The INION Thermo water bath is a medical, electrical device
intended for continuous operation. Its purpose is to provide
a safe, simple and effective method of preparing heated water
for use with INION products.
2. Indications for Use
The INION Thermo water bath, in conjunction with the Thermo
Drape (Ref. No. ACC-9802), is intended to heat sterile liquid
to approximately 55 C +/- 5 C and maintain a relative temperature
for the thermo-forming of appropriate INION implants.
3. Instructions for Use
Operation of the INION Thermo water bath requires connection
to a 220 - 240 VAC 50 Hz, minimum 1 A outlet.
The Thermo Drape (Ref. No. ACC-9802) must be placed
over the unit before adding liquid to the tank.
Fill the tank with sterile water. Full capacity of
the tank is approximately 0.7 litres. INION recommends that
a minimum of 0,4 litre should be maintained in the tank.
After connection to the outlet, the green power switch
must be in the "ON" position. The signal lamp and
"ON/OFF" marking adjacent to the switch will indicate
whether the power is on or off. When operating the switch,
support the device from behind.
The liquid in the tank will attain the preferred temperature,
approximately 55 C +/- 5 C, 20 minutes after the power is
switched on. The use of warm sterilised fluid will shorten
the heating time.
After use, return the green power indicator switch
to the "OFF" position and disconnect the device
from the electrical outlet. It is recommended that the unit
is allowed to cool to room temperature before returning it
to a safe storage area. Dispose of the fluid according to
safe operating room procedures.
4. Prohibitions for Use
Do not use with screws
Do not use the INION Thermo water bath without the
Thermo Drape
(Ref. No. ACC-9802) or with other manufacturers' drapes
Do not use with other manufacturers' products or implants
Do not drape the INION Thermo water bath when hot
Do not use with non-sterile liquids
Do not use with less than 0.4 litre of liquid
Do not use with power supplies other than those recommended
on
the device
Do not use with sharp or pointed instruments
Do not use on or near the patient
Do not use on unstable stands or carts
5. Cleaning and Sterilisation
The INION Thermo water bath is provided non-sterile.
The Thermo Drape (Ref. No. ACC-9802) must be used at all times
to ensure the sterility of the liquid poured into the draped
tank.
The INION Thermo water bath may be cleaned after use
by using a damp cloth and warm water or diluted cleaning solution.
The INION Thermo water bath cannot be sterilised.
6. Storage and Handling
Transportation and storage under controlled conditions,
temperature 15 - 30 C, relative humidity below 60%.
The device must be properly cleaned immediately after
use.
It is recommended that the original packaging for the
INION Thermo water bath should be used when transporting the
device.
7. Service and Maintenance
There are no parts in the INION Thermo water bath that
requires servising.
No maintenance is necessary. However, in case of malfunction,
please
return the INION Thermo water bath to the manufacturer,
FINNSONIC OY, Parikankatu 8, 15170 Lahti, Finland. Do not
attempt to
service.
8. Warnings
Turn off immediately after use.
Do not use the device without fluid in the tank.
Do not remove the bottom plate. Return to FINNSONIC
for service.
Caution: Contains hot fluid (55 C)
9. Technical Data
Tank volume: Max. 0.7 litres
Heating power: 150 W
Fuses: 2 x 1,0 AF, 5 x 20 mm
Electric connection: 220 - 240 VAC 50 - 60 Hz
Connection power: 150 W
Main fuse: 1 x 10 A
Supply cable: 3 x 0,75S
Ideal Implant
The
ideal implant for craniomaxillofacial (CMF) surgery
The ideal implant would be made of a biodegradable material,
which
1.
Can be fabricated and designed with appropriate initial strength
to meet the biomechanical demands;
2. Degrades in a predictable manner and allows for safe progressive
loading during the bone-healing process;
3. Causes no tissue response necessitating device removal;
and
4. Disappears completely.

Plates
will degrade gradually as bone starts to bear loading
30 Years Of Excellent Results With Biodegradable
Implants
Biodegradable polymers have been used in surgical applications
for the past 30 years as suture materials and bone fixation
devices. In the last two decades, the use of biodegradable
materials has expanded to include a number of other fixation
applications. Since the 1970s, the excellent biocompatibility
of the polymers used by Inion Ltd. has been documented in
hundreds of scientific articles.
|